What tests need to be done after the heat sealing of membrane structure membrane fabric?

Post-heat-sealing Inspection Items for Membrane Structure Fabric:

Appearance Inspection: Check for smooth welds, free of bubbles, wrinkles, or impurities, ensuring no incomplete or missed welds.

Dimensional Inspection: Measure heat-sealed dimensions and errors.

Strength Inspection: Test tensile strength through a tensile test.

Sealing Inspection: Check the watertightness of welds to ensure no leakage.

Weather Resistance Inspection: Simulate ultraviolet radiation, high temperature, and other environments to assess long-term performance changes.

Testing Methods:

Physical Testing: Measure tensile strength using a tensile testing machine.

Auxiliary Instruments: Thickness gauge, air permeability tester, etc.

Precautions:
The testing environment must meet standards.

Clean the membrane surface after testing to avoid scratching the coating.